Pump for Detector Tubes Application CHP-5

CHP-5 is the mobile equipment for detection of chemical warfare agents and toxic industrial compounds in the air, on the ground and ground objects, using detection tubes.

The CHP-5 is equipped with a pumping set, which pumps the air into detecting tubes through the inlet.

If the air is contaminated by warfare chemical agents or industrial toxic chemicals, the indication layers of the detecting tubes change the colour. The type and concentration of individual chemicals can be evaluated using the etalons on detection tube package.

description

download

gallery

Features:

  • One up to five detection tubes applied together
  • Possible to set flow rate and time
  • When running, fully automatic control of flow rate at the level adjusted
  • Indication and display of temperature inside the working chamber when working
  • Electric heating the tubes before and during air sucking to a proper temperature
  • Indication and display of temperature outside the equipment
  • Lighting the working chamber with tubes
  • Lighting the display
  • Testing the working chamber and the pneumatic system tightness
  • Testing the air valves function
  • Display of real time
  • Datum display
  • Li-Ion battery control and display of the level
  • Measurement the maximal possible flow through the tube

Specifications:

Parameter  
Instrument size (without the battery) 230(l) x 82(w) x 161(h) mm
Size including the  Li-Ion battery 230(l) x 82(w) x 210(h) mm
Instrument Weight (without the battery) 2,8 kg
Weight including the Li-Ion battery 4,4 kg
Total weight with accessories Max. 6 kg
Staff 1 person trained
Power source Battery 15 V Li-Ion / Vehicle source 12V – 40V
Working time with one charging 6 hours  continuously
Max. flow rate total 5 l/min
Min. flow rate 0,3 l/min
Flow rate accuracy 0,1 l/min
Number of tubes applied 1 - 5
Working temperature -20 up to +50 °C
Time to prepare equipment for detection Max. 10 minutes (including eventual heating)

 